6.3.

Set up

6.3.1.

Thermostat

First touch SETUP, then touch THERMOSTAT to set up the parameters for the
Evolutionr Connex Control.
6.3.1.1.

Auto Mode set up

Once the auto changeover option has been selected, touch SAVE.
Enable or Disable: Choose to enable or disable auto changeover mode
S
Default = Enable
d
Auto changeover time: Adjustable from 5 to 120 minutes
S
Default = 30 minutes
d
6.3.1.2.

Heat/Cool Deadband

The minimum difference enforced between heating and cooling desired
temperatures. This can allow one setting to "push" the other to maintain this
difference. When the correct deadband is set, touch SAVE.
Deadband: Adjustable from 0 to 6_F (0 to 2_C)
S