Sound Ratings; Electrical Data; Outdoor Units; Indoor Units - Carrier 40QNC Product Data

High-wall duct free split system
Hide thumbs Also See for 40QNC:
Table of Contents

Advertisement

SOUND RATINGS

Outdoor Units

Model Number
38HDF018 --- --- ---3
38HDF024 --- --- ---3
38HDF030 --- --- ---3
38HDF036 --- --- ---3/5/6
38QRF018 --- --- ---3
38QRF024 --- --- ---3
38QRF030 --- --- ---3
38QRF036 --- --- ---3/5/6

Indoor Units

Model Number
Sound Power
40QNC01824 --- --- ---3
40QNC030 --- --- ---3
40QNC036 --- --- ---3
40QNQ018 --- --- ---3
59/60 (Clg/Htg)
40QNQ024 --- --- ---3
59/60 (Clg/Htg)
40QNQ030 --- --- ---3
60/61(Clg/Htg)
40QNQ036 --- --- ---3
62/63 (Clg/Htg)
NOTES:
1. Sound power ratings are tested in accordance with ARI standard 270 --- --- ---95 (not listed in ARI) and ARI 350.
2. Sound pressure ratings are estimated sound pressure, 3 feet (.91 m) from the unit, based on sound power data.
WIRING
The indoor and outdoor units have their own power supply. Low voltage control wires run between the indoor and outdoor units. Two wires
are required for cooling only systems and seven wires are required for heat pumps.

ELECTRICAL DATA

38HDF/38QRF
V--- PH --- Hz
UNIT SIZE
018
208/230 ---1 ---60
024
208/230 ---1 ---60
030
208/230 ---1 ---60
208/230 ---1 ---60
036
208/230 ---3 ---60
460 ---3 ---60
UNIT SIZE
V--- PH --- Hz
40QNC01824
208/230 ---1 ---60
40QNC030
208/230 ---1 ---60
40QNC036
208/230 ---1 ---60
40QNQ018
208/230 ---1 ---60
40QNQ024
208/230 ---1 ---60
40QNQ030
208/230 ---1 ---60
40QNQ036
208/230 ---1 ---60
*Permissible limits of the voltage range at which unit will operate satisfactorily.
LEGEND
FLA
--- Full Load Amps
MCA
--- Minimum Circuit Amps per NEC Section 430 ---24
NEC
--- National Electrical Code
RLA
--- Rated Load Amps (Compressor)
Sound Power dBa
66
66
72
72
66
66
72
72
High
Sound Pressure
dBa
dBa
59
48
60
49
62
51
48/49 (Clg/Htg)
48/49 (Clg/Htg)
49/50 (Clg/Htg)
51/52 (Clg/Htg)
38HDF/38QRF ELECTRICAL DATA
VOLTAGE RANGE*
Min
Max
187
253
187
253
187
253
187
253
187
253
414
506
40QNC, QNQ FAN COIL ELECTRICAL DATA
VOLTAGE RANGE*
Min
Max
187
253
187
253
187
253
187
253
187
253
187
253
187
253
Medium
Sound Power
Sound Pressure
dBa
dBa
53
42
57
46
60
49
53/54 (Clg/Htg)
42/43 (Clg/Htg)
53/54 (Clg/Htg)
42/43 (Clg/Htg)
57/58 (Clg/Htg)
46/47 (Clg/Htg)
60/61 (Clg/Htg)
49/50 (Clg/Htg)
COMPRESSOR
OUTDOOR FAN MOTOR
RLA
LRA
FLA
9.0
48.0
0.80
12.8
58.3
0.80
14.1
73.0
1.50
17.9
112.0
1.45
13.2
88.0
1.45
6.0
44.0
0.80
FAN
Motor Power
FLA
(Watts)
0.38
0.38
0.44
0.38
0.38
0.38
0.44
1. In compliance with NEC requirements for multi---motor and combination
load equipment (refer to NEC Articles 430 and 440), the overcurrent
protective device for the unit shall be fuse or equipped with a breaker.
2. Motor RLA values are established in accordance with UL (Underwriters
Laboratories) Standard 465.
26
Sound Pressure dBa
55
55
61
61
55
55
61
61
Low
Sound Power
Sound Pressure
dBa
49
53
57
49/50 (Clg/Htg)
38/39 (Clg/Htg)
49/50 (Clg/Htg)
38/39 (Clg/Htg)
53/55 (Clg/Htg)
42/44 (Clg/Htg)
57/58 (Clg/Htg)
46/47 (Clg/Htg)
MIN CKT
AMPS
NEC Hp
kW Out
0.125
0.09
12.1
0.125
0.09
16.8
0.25
0.19
18.4
0.25
0.19
23.8
0.25
0.19
18.0
0.25
0.19
8.3
POWER
MIN CKT
AMPS
64
0.48
74
0.48
74
0.55
64
0.48
64
0.48
74
0.48
74
0.55
NOTES:
®
dBa
38
5
46
FUSE/
CKT
BKR
AMPS
20
25
30
40
30
15
FUSE/CKT
BKR AMPS
15
15
15
15
15
15
15