Vent System Identification - Empire Comfort Systems Tahoe DVP36PP32EN-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for Tahoe DVP36PP32EN-1:
Table of Contents

Advertisement

Installing Vent Components (Figure 46)
Begin the vent system installation by installing the first Simpson Duravent
component, 90° elbow to the starting collars or straight pipe on the top of
the appliance, then the straight pipe length and then horizontal or vertical
termination kit.
NOTE: All outer connection joints must be sealed with aluminum
tape, screws or silicone sealant rated above 300°F/149°C. The inner
flue joints do not require any sealant.
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRESTOP
WALL STRAP
PIPE LENGTH
24325-0-0708
VENT SYSTEM IDENTIFICATION
Figure 46
Simpson Duravent vent system components lock into place by sliding the
concentric pipe section with four (4) equally spaced interior beads onto
the appliance collar or previously installed component end with four (4)
equally spaced indented sections. When the internal beads of each starting
outer pipe line up, rotate pipe section clockwise 90° (approximately 3
inches). The vent pipe is now locked together.
Continue adding components per the pre-planned vent system configuration.
Be certain that each succeeding vent component is securely fitted and
locked into the preceding component in the vent system.
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
TWO 90° ELBOWS)
Special venting components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and
pricing.
Available from Empire Comfort Systems, Inc. dealers.
DVVK-4VP
Direct-Vent Fireplace Vent Kit - Vertical, Includes SD46DVAF6,
(DVVK-4V)
SD46DVASC, and SD46DVAVCH
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to 11 inch
DVVK-4TP
wall thickness, Includes SD46DVA08A, SD46DVA09, SD46DVAE90,
(DVVK-4T)
SD46DVAHC, and SD46DVAWT
Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall thickness,
DVVK-4RP
(standard thru-the-wall venting) includes SD46DVA06, SD46DVAHC,
(DVVK-4R)
and SD46DVAWT.
Direct-Vent Fireplace Vent Kit For Rear Vent, Thru-the-wall for 5 to
DVVK-4RE
13 3/4 inch wall thickness.
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to 7 inch
DVVK-4TSP
wall thickness, Includes SD46DVA06, SD46DVAE90, SD46DVAHC,
(DVVK-4TS)
and SD46DVAWT.
DVVK-4FV
Vertical Flex Vent Kit 4" x 7"
VIB6A
Vertical Inlet Baffle Kit For 6 5/8" diameter
VIB7A
Vertical Inlet Baffle Kit For 7" diameter
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90° ELBOWS)
STORM COLLAR
ROOF FLASHING
Special DV Vent Kits
Page 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents