Command Quick Reference; Command Set For The Ppla - AMT Datasouth Fastmark 400 Series User Manual

Amt datasouth barcode label printer user's guide 400
Table of Contents

Advertisement

COMMAND QUICK REFERENCE

This section lists all software commands of the printer.

Command Set for the PPLA

System Setting Commands
These commands will cause related parameters to be saved in the non-volatile memory. These
parameters will be stored unless other commands or a front panel reset changes them.
Command
<STX>KI4n
<STX>KI5nn Set gap length
<STX>KI7n
<STX>KI8n
<STX>KI;n
<STX>KI<m Set symbol set for ASD
Note: <STX>KI7n command is ignored by model FM402DT
User's Guide 26
Description
Media empty check
Set transfer type
Set baud rate
Set standard control
code.
Set alternative control
code.
smooth font set
Parameter
n : 0 - disable,
1 - enable.
nn: 01 to 10 (mm)
n : 0 - direct thermal,
1 - thermal transfer.
n : 0 - 9600,
1 - 2400, 2 - 2400,
3 - 19200, 4 - 4800,
5 - 38400, 6 - 2400,
7 - 9600 baud.
n: 1 - Standard control
code
2 - alternate control
code
m : 0 - USASCII,
1 - United Kingdom,
2 - Spanish,
3 - Swedish,
4 - French,
5 - German,
6 - Italian,
7 - Danish/Norwegian.
Factory default
1
1
1
0
1
0

Advertisement

Table of Contents
loading

Table of Contents