The Gas Supplier; Safety; Www.desatech.com - Desa CD36RN Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

WARNING: The glass door
must be securely in place before
running this fireplace. Do not run
this fireplace if glass is missing
or broken.
4. Open bag of ember materials.
5. Break apart about quarter sized pieces
and place a single layer along full length
of ember tray to hide bottom edge of base
log (see Figure 60).
6. Replace glass door and louver panels.
See Removing/Replacing Glass Door,
page 30.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance is equipped with an igni-
tion device which automatically lights
the pilot. Do not light pilot by hand.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Open lower louver panel.
3. Turn off all electric power to fireplace.
4. Push in gas control knob slightly and turn
clockwise to OFF (see Figure 61).
5. Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you
don't smell gas go to the next step.
3
FIREPLACE INSTALLATION
Continued
OPERATION
MILLIVOLT MODELS

www.desatech.com

Ember
Material
Ember
Tray
Figure 60 - Applying Ember Material
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been under
water.
6. Pilot is located by main burner and should
not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT.
Gas Control
Variable
Knob
Control Knob
IN
OUT
Figure 61 - Control Valve
Piezo
Ignitor
LO
116035-01J