Www.desatech.com - Desa CD36RN Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

VENTING INSTALLATION
Continued
vertical Termination Configurations for
Top vent
Figures 31 and 34 show four different configu-
rations for vertical termination.
VERTICAL VENT INSTALLATIONS USING
MULTIPLE 90° ELBOWS (V)CD36T TOP
VENT
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.
90° Elbow
venting with Three 90° Elbows
vertical (v)
8' Min.
10' Min.
12' Min.
14' Min.
16' Min.
18' Min.
40' Max.
Figure 31 - Vertical Venting
Configuration using Three 90° Elbows
(Model (V)CD36T with Vertical Round
High Wind Termination)
0
Horizontal (H
) +
1
Horizontal (H
)
2
5' Max
8' Max
11' Max
14' Max
17' Max
20' Max
20' Max

www.desatech.com

venting with Two 90° Elbows
vertical (v)
8' Min.
9' Min.
10' Min.
12' Min.
14' Min.
40' Max.
90° Elbow
Figure 32 - Vertical Venting
Configuration Using Two 90° Elbows
(Model (V)CD36T with Vertical Round
High Wind Termination)
90°
Elbow
Note: Vertical (V
) + Vertical (V
1
Max. Horizontal Above 14' Vertical = 20'
Figure 33 - Vertical Venting
Configuration Using Two 90° Elbows
(Model (V)CD36T with Vertical Round
High Wind Termination)
Horizontal (H)
6' Max
8' Max
10' Max
14' Max
18' Max
20' Max
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination cap.
venting with Two 90°
Elbows
vertical
Horizontal
(v
)
(H)
1
8' Min.
9' Max
9' Min.
11' Max
10' Min.
13' Max
12' Min.
17' Max
14' Min.
20' Max
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination cap.
) = 40' Max.