Curtis GEM-612ILD Installation Instructions, Service & Warranty Information page 3

Digital gemini high volume brewing systems

Advertisement

STEPS TO
PROGRAMMING ONLY REQUIRED IF FACTORY SETTINGS MUST BE CHANGED
PROGRAMMING
IMPORTANT – Before entering the program mode, allow the unit to reach brewing
temperature, then press the BREW button to dispense at least 12 ounces of water to
WARNING These steps
clear any air within the water lines.
involve working with hot
Program Tamper Switch
water. Scalding may occur if
care is not taken against spilling.
To enable programming, turn on the Program Switch on the control board (See illustration, right). On
the Gem-612 & TL9002 DOWN is on. On the Gem-600 & TL9001 Left (while facing unit) is on.
NOTE:
NOTE:
NOTE:
NOTE:
NOTE: For ALL functions
Upon completion of programming, the switch can be returned to its normal (tamperproof) position or
you must first enter the
allowed to remain in the on position.
programming mode.
Brew Temperature – Factory Pre-Set to 200°F
Function to set brew temperature, 170° to 204°F. Brew temperature will be indicated by READY-TO-BREW light
blinking.
ENTERING THE PROGRAM MODE #1
" Turn OFF the power from the Control Panel by pressing
.
" Press and HOLD
and press and RELEASE
.
" Continue HOLDING
until
starts blinking; RELEASE.
READY TO BREW
BREW VOLUME - Factory Preset to Brewer Requirements
BREW CYCLE COUNTER
ENTER THE PROGRAM MODE #2
" Turn OFF the power from the Control Panel by pressing
.
" Press and HOLD
and press and RELEASE
.
" Continue HOLDING
until
STOPS blinking; RELEASE.
READY TO BREW
SLEEP MODE (220V Models Only) – Factory Preset to Disabled
WARMERS
Adjusting the Temperature
Gemini Warmers feature three temperature settings. Warmers are rated at 90W with High (100%); Med
(60%); Low (30%). Pressing the WARMER button once will place it on HIGH; A second time MED; Third
time LOW as indicated by the warmer lights. A fourth press of the warmer button turns off the warmer.
When the system is turned off at the ON/OFF button, it will remember the last warmer setting. Additionally,
if the warmer is off, the unit is designed to automatically turn the warmer on (MED setting) when the BREW
button is pressed.
BYPASS FLOW ADJUSTMENT
BYPASS FLOW ADJUSTMENT
BYPASS FLOW ADJUSTMENT
BYPASS FLOW ADJUSTMENT
BYPASS FLOW ADJUSTMENT
1. Slide brew cone out to expose bypass outlet. Place one measuring cup under the bypass fitting, and another measuring cup under the brew cone outlet. Press the LARGE brew button for 15 seconds,
then press the ON/OFF button to stop the brew cycle.
2. Divide the number of ounces collected from the bypass outlet into the total ounces collected from the sprayhead and bypass. This will determine the percentage of bypass.
3. To increase or decrease the volume of bypass water, turn the adjustment screw on the bypass valve as indicated. Clockwise for less water; counterclockwise for more water.
4. You must reprogram the brew volume to maintain the proper total amount of coffee brewed into the insulated server. Reprogramming is required every time you make a bypass
adjustment or change to a different sprayhead.
2
CONTROL BOARD
CONFIRM/RESET BREW TEMPERATURE - Factory Preset to 200º
ENTER THE PROGRAMMING MODE #1:
" Press
for two seconds, then RELEASE.
"
will start blinking. Each blink equals 2º F, starting at 170º.
READY TO BREW
" To change Temperature, press and HOLD
.
.
"
will start QUICK flashing. Each QUICK flash equals 2º F.
READY TO BREW
After reaching 204º, temperature starts over at 170º.
" RELEASE
when the desired temperature is reached.
To set and exit, press
.
CHANGE BREW VOLUME
ENTER THE PROGRAMMING MODE #1
" Press and HOLD
until hot water starts running from sprayhead; then RELEASE.
" When desired volume is reached, press
again to stop flow.
" To set and exit, press
.
TO ACCESS BREW CYCLE COUNTER
ENTER THE PROGRAMMING MODE #2:
"
will now start a pattern of LONG and SHORT blinks.
READY TO BREW
This pattern identifies the number of brew cycles. SHORT blinks indicate the brew number from one [1] to
nine [9]. LONG blinks separate the 1's, 10's, 1,000's and 10,000's.
This function conserves energy by automatically reducing tank temperature to 140º F when the unit sits idle for
more than two hours. To recover, simply press any BREW (or Grind button if InterLocked) or ON/OFF button. Once the
water in the tank reaches brewing temperature, the brew cycle will automatically start. Recovery is indicated by a
yellow RECOVERY light on the membrane control panel. Recovering from a SLEEP mode is faster and more efficient
than heating after switching off the power.
SLEEP MODE – Factory Preset to DISABLED
To ENABLE Sleep Mode:
" UNIT MUST BE ON. Press and HOLD
until
SLEEP light turns ON; press
Sleep Mode is now ENABLED.
To DISABLE Sleep Mode:
" UNIT MUST BE ON. Press and HOLD
until
SLEEP light turns OFF;press
Sleep Mode is now ENABLED.
To Determine Warmer Setting and Change Time:
" WARMER MUST BE OFF. Press and HOLD
until the light comes ON and goes OFF; RELEASE.
" The light will start blinking. Count the blinks. Each blink=20 minutes (maximum 200 min.).
" At the end of the cycle, press and HOLD
until the light begins QUICK flashing. The cycle will start over
after 11 flashes (Note - A setting of 11 flashes is the OFF position).
" When the desired time is reache, RELEASE
.
" To set and exit, press
.
again.
again.