Drain Pan; Freeze Protection; Furnace Suspension; Lternate Lectrical And As Ine Onnections - Goodman GMS95 Installation Instructions Manual

Gas-fired warm air furnace
Table of Contents

Advertisement

AIR
ALTERNATE FLUE AND
DISCHARGE
COMBUSTION AIR PIPE
LOCATIONS
Side
Side
Return
Return
Duct
Duct
Connection
Connection
Bottom
Return
Duct
Connection
UPFLOW
UPRIGHT
ALTERNATE FLUE AND
COMBUSTION AIR PIPE
LOCATIONS
Bottom
Return
AIR
Duct
DISCHARGE
Connection
UPFLOW HORIZONTAL
LEFT AIR DISCHARGE
Bottom
Return
Duct
DISCHARGE
Connection
UPFLOW HORIZONTAL
RIGHT AIR DISCHARGE
Recommended Installation Positions
NOTE: Alternate "vertical" piping connections can not be used when
an upflow furnace is installed with supply air discharging to the right,
or when a counterflow furnace is installed with supply air discharging
to the left. In either case, use the standard flue and combustion air
piping connections.
A
E
LTERNATE
LECTRICAL AND
This furnace has provisions allowing for electrical and gas line con-
nections through either side panel. In horizontal applications the
connections can be made either through the "top" or "bottom" of the
furnace.
D
P
RAIN
AN
A drain pan must be provided if the furnace is installed above a con-
ditioned area. The drain pan must cover the entire area under the
furnace (and air conditioning coil if applicable).
F
P
REEZE
ROTECTION
Refer to Section VII, Horizontal Applications and Conditions - Drain
Trap and Lines.
F
S
URNACE
USPENSION
If the furnace is installed in a crawl space it must be suspended from
the floor joist or supported by a concrete pad. Never install the fur-
nace on the ground or allow it to be exposed to water. Refer to
Section IV, Location Requirements and Considerations - Furnace
Suspension for further details.
VIII. PR
VIII. PRO O O O O P P P P P ANE GA
VIII. PR
VIII. PR
VIII. PR
ANE GA
ANE GA
ANE GAS /HI
ANE GA
S /HIGH AL
S /HI
S /HI
S /HI
P
OSSIBLE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH MAY OCCUR IF
THE CORRECT CONVERSION KITS ARE NOT INSTALLED.
MUST BE APPLIED TO INSURE SAFE AND PROPER FURNACE OPERATION.
CONVERSIONS MUST BE PERFORMED BY A QUALIFIED INSTALLER OR SERVICE
AGENCY.
ALTERNATE FLUE AND
Bottom
COMBUSTION AIR PIPE
Return
LOCATIONS
Duct
Connection
AIR
DISCHARGE
COUNTERFLOW
UPRIGHT
ALTERNATE FLUE AND
COMBUSTION AIR PIPE
LOCATIONS
Bottom
Return
Duct
Connection
COUNTERFLOW HORIZONTAL
RIGHT AIR DISCHARGE
AIR
AIR
DISCHARGE
COUNTERFLOW HORIZONTAL
LEFT AIR DISCHARGE
G
L
C
AS
INE
ONNECTIONS
GH AL
GH ALTITUD
GH AL
GH AL
TITUD
TITUD
TITUDE INST
TITUD
E INST
E INSTALL
E INST
E INST
ALLA A A A A TI
ALL
ALL
ALL
WARNING
T
HE APPROPRIATE KITS
This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
change to compensate for the energy content difference between
natural and propane gas.
High altitude installations may require both a pressure switch and an
orifice change. These changes are necessary to compensate for
the natural reduction in the density of both the gas fuel and the com-
bustion air at higher altitude.
For installations above 7000 feet, please refer to your distributor for
required kit(s).
Altitude
AIR
0-7000
DISCHARGE
NOTE: In Canada, gas furnaces are certified to 4500 feet.
Contact the distributor for a tabular listing of appropriate
Bottom
manufacturer's kits for propane gas and/or high altitude installa-
Return
Duct
tions. The indicated kits must be used to insure safe and proper
Connection
furnace operation. All conversions must be performed by a quali-
fied installer, or service agency.
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
IX. VENT/FLUE PIPE & COMBUSTION AIR PIPE
G

ENERAL

F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN BODILY INJURY OR
C
DEATH.
AREFULLY READ AND FOLLOW ALL INSTRUCTIONS GIVEN IN THIS
SECTION.
U
PON COMPLETION OF THE FURNACE INSTALLATION, CAREFULLY INSPECT THE
ENTIRE FLUE SYSTEM BOTH INSIDE AND OUTSIDE THE FURNACE TO ASSURE IT
IS PROPERLY SEALED.
PERSONAL INJURY OR DEATH DUE TO EXPOSURE TO FLUE PRODUCTS,
INCLUDING CARBON MONOXIDE.
A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place. Be-
cause of the relatively low flue gas temperature and water conden-
sation requirements, PVC pipe is used as venting material.
This furnace must not be connected to Type B, BW, or L vent or vent
connector, and must not be vented into any portion of a factory built
or masonry chimney except when used as a pathway for PVC as
described later in this section. Never common vent this appliance
with another appliance or use a vent which is used by a solid fuel
appliance. Do not use commercially available "no hub connectors"
TIO O O O O NS
TI
TI
TI
NS
NS
NS
NS
other than those shipped with this product.
It is the responsibility of the installer to follow the manufacturers'
recommendations and to verify that all vent/flue piping and connec-
tors are compatible with furnace flue products. Additionally, it is the
responsibility of the installer to ensure that all piping and connec-
tions possess adequate structural integrity and support to prevent
flue pipe separation, shifting, or sagging during furnace operation.
A
LL
12
HIGH ALTITUDE GAS ORIFICE CHART
Gas
Kit
Orifice
Natural
None
#43
Propane
LPT-00A
#55
WARNING
WARNING
L
EAKS IN THE FLUE SYSTEM CAN RESULT IN SERIOUS
Manifold
Pressure
Pressure
Switch
3.5" w.c.
None
10.0" w.c.