8. Clean the primary heat exchanger tubes using a wire brush
attached to a length of high grade stainless steel cable,
such as drain cleanout cable. Attach a variable speed
reversible drill to the other end of the cable. Slowly rotate
the cable with the drill and insert it into one of the heat
exchanger tubes. While reversing the drill, work the cable
in and out several times to obtain sufficient cleaning. Repeat
for each tube.
9. Clean residue from furnace using a vacuum cleaner.
10. Replace the parts removed in the previous steps in reverse
order.
11. Turn on electrical power and gas to furnace. Check for
leaks and proper unit operation.
12. Severe heat exchanger fouling is an indication of an
operational problem. Perform the checks listed in Section
XIV, Startup Procedure and Adjustments to reduce the
chances of repeated fouling.
X X X X X X. INTERNAL FIL
X. INTERNAL FIL
X. INTERNAL FIL
X. INTERNAL FILTER REM
X. INTERNAL FIL
Internal filters are an accessory item and are not included with your
furnace. For further details, see your distributor.
B
R
R
OTTOM
ETURN
EMOVAL
1. Turn OFF electrical power to furnace.
2. Remove blower compartment door.
3. Push back and up on the wire filter retainer to release it
from under the front lip of the furnace basepan.
4. Slide filter forward and out.
5. Replace filter by reversing the procedure.
B
C
R
LOWER
OMPARTMENT
1. Turn OFF electrical power to furnace.
2. Remove blower compartment door.
3. Grasp lower portion of filter and lift up.
Front of Furnace
Blower
Grab Here
And Lift
TER REM
TER REM
OV
OV
AL
AL
TER REMOV
TER REM
OVAL
OV
AL
AL
EMOVAL
Front of Furnace
Blower
4. Angle filter toward the blower until filter clears bottom rail.
5. Lower filter down and pull outward.
Front of Furnace
Blower
6. Replace filter by reversing procedure.
X X X X X XI. BEFO
XI. BEFO
XI. BEFO
RE LEA
RE LEA
XI. BEFO
XI. BEFORE LEA
RE LEA
RE LEAVIN
Cycle the furnace with the thermostat at least three times.
Verify cooling and fan only operation.
Review the Owner's Manual with the homeowner and
discuss proper furnace operation and maintenance.
Leave literature packet near furnace.
X X X X X XII. REP
XII. REPAIR & REPL
XII. REP
XII. REP
XII. REP
AIR & REPL
AIR & REPL
AIR & REPL
AIR & REPLACEMENT PAR
When ordering any of the listed functional parts, be sure to
provide the furnace model, manufacturing, and serial
numbers with the order.
Although only functional parts are shown in the parts list, all
sheet metal parts, doors, etc. may be ordered by description.
Parts are available from your distributor.
Functional Parts List-
Gas Valve
Gas Manifold
Natural Gas Orifice
Propane Gas Orifice
Igniter
Flame Sensor
Rollout Limit Switch
Primary Limit Switch
Auxiliary Limit Switch
Pressure Switch
Induced Draft Blower
Door Switch
33
Front of Furnace
Blower
VIN
VIN
G AN INST
G AN INST
ALL
ALLA A A A A TI
ALL
TI TI
TIO O O O O N N N N N
TI
VIN
VING AN INST
G AN INST
G AN INSTALL
ALL
ACEMENT PARTS
ACEMENT PAR
ACEMENT PAR
ACEMENT PAR
TS
TS
TS
TS
Blower Motor
Blower Wheel
Blower Mounting Bracket
Blower Cutoff
Blower Housing
Capacitor
Heat Exchanger
Recuperator Coil
Coil Front Cover
Integrated Control Module
Transformer