OBSERVED PROBLEM
Yellow flame in front/middle
burner during burner combus-
tion (VRL and CSG models)
Slight smoke or odor during
initial operation
Heater produces a whistling
noise when burners are lit
White powder residue forming
within burner box or on adja-
cent walls or furniture
Moisture/condensation no-
ticed on windows
Remote does not function
Heater produces a clicking/
ticking noise just after burners
are lit or shut off
30
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Not enough air
2. Gas regulator defective
1. Residues from manufac-
turing processes and logs
curing
1. Turning control knob to HI
position when burners are
cold
2. Air in gas line
3. Air passageways on heater
blocked
4. Dirty or partially clogged
burner orifice(s)
1. When heated, vapors from
furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue
1. Not enough combustion/
ventilation air
1. Battery is not installed. Bat-
tery power is low
1. Metal expanding while heat-
ing or contracting while
cooling
www.desatech.com
REMEDY
1. Check burner(s) for dirt
and debris. If found, clean
burner(s) (see Cleaning and
Maintenance, page 26)
2. Replace gas regulator
1. Problem will stop after a few
hours of operation
1. Turn control knob to LO
position and let warm up
for a minute
2. Operate burners until air is
removed from line. Have
gas line checked by local
natural or propane/LP gas
company
3. Observe minimum installation
clearances (see page 8)
4. Clean burners (see Cleaning
and Maintenance, page 26)
1. Turn heater off when us-
ing furniture polish, wax,
carpet cleaners or similar
products
1. Refer to Air for Combustion
and Ventilation require-
ments (page 6)
1. Replace 9-volt batteries
in receiver and hand-held
remote
1. This is normal with most
heaters. If noise is exces-
sive, contact qualified ser-
vice person