Desa VRL24NR Owner's Manual page 13

24/30" remote-ready/thermostat models unvented gas log heater
Table of Contents

Advertisement

INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
(Remote-Ready Models Only)
Note: When used as a vented heater, ap-
pliance must be installed only in a solid-fuel
burning fireplace with a working flue and con-
structed of noncombustible material.
For Massachusetts Residents Only: Instal-
lation of this vented gas log set in the Com-
monwealth of Massachusetts requires the
damper be permanently removed or welded
in the fully open position.
If your heater is a manually-controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.
1. The fireplace does not meet the clearance
to combustibles requirements for vent-
free operation.
2. State or local codes do not permit vent-
free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
41). This will insure vented operation (see Fig-
ure 10). The damper clamp will keep damper
open. Installation instructions are included
with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper
clamp so the minimum permanent flue open-
ing will be maintained at all times.
Area of Various Standard Round Flues
Diameter
5"
6"
7"
8"
Chimney
Height
6' to 15'
15' to 30'
110021-01S
INSTALLATION
Area
20 sq. inches
29 sq. inches
39 sq. inches
51 sq. inches
Minimum Permanent
Flue Opening
39 sq. inches
29 sq. inches
www.desatech.com
Continued
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
INSTALLING HEATER BASE
ASSEMBLY
CAUTION: Do not remove the
data plates attached to the heater
base assembly. The data plates
contain important warranty and
safety information.
WARNING: If installing in a
sunken fireplace, special care
is needed. You must raise the
fireplace floor to allow access
to heater control panel. This
will insure adequate air flow
and guard against sooting and
controls being damaged. Raise
fireplace floor with noncombus-
tible material. Make sure material
is secure.
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base as-
sembly by grates.
Damper
Clamp
Damper
Manufactured
Fireplace
Damper
13