Determining Minimum Mantel Clearance
when Using a Hood
If minimum clearances in Figure 6 (see page 11)
are not met, you must have a hood. When using
a hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using a hood.
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
firebox may become hot to
the touch. If installed properly,
these temperatures meet the
requirement of the national
product standard. Follow all
minimum clearances shown in
this manual.
Minimum
Noncombustible
Material
Figure 7 - Minimum Mantel Clearances When Using Hood
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
12
INSTALLATION
Continued
12"
10"
8"
6"
2½"
Hood
(GA6050,
GA6052 or
GA6053)
Combustible
Material
14"
Min.
Noncombustible Material
www.desatech.com
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the floor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).
Mantel Shelf
8"
12" 15"
18" 20"
Min.
Distances to
Underside of
Mantel
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Underside
of Mantel
Shelf
Top of
Fireplace
Opening
Hearth
Combustible
Material
5"
Min.
110021-01S