Appliance Preparation; Installing Ak14 Outside Air Kit - Heatilator CB4236IR Owner's Manual

B-vent gas appliance
Hide thumbs Also See for CB4236IR:
Table of Contents

Advertisement

7 7

Appliance Preparation

CAUTION
Sharp Edges
Wear protective gloves
and safety glasses during
installation.
WARNING
Fire Risk
Asphyxiation Risk
Maintain vent clearance to combustibles as
specifi ed.
Do not pack air space with insulation or
other materials.
National building codes recommend
using attic shield to keep loose materials/
insulation from contacting vent.
Failure to keep insulation or other materials
away from vent pipe may cause fi re.
A. Installing AK14 Outside Air Kit
This appliance will operate correctly only if adequate ventia-
tion is provided to allow proper draft to the system.
An outside air kit is available as an optional feature with this
appliance. An outside air kit helps to decrease the amount
of room air taken by utilizing outside air for combustion. We
strongly recommend that it be installed.
Note: The outside air kit inlet thimble should be positioned
in a manner that will not allow snow, leaves, etc. to block
the inlet. A 3 ft. (.91 m) minimum height difference must be
maintained from the top of the uppemost chimney section to
the outside combustion air inlet. Reference Section 2.
The outside air kit can only be installed on the left side of
the appliance.
Refer to the installation instructions provided with the kit
and Figure 7.3.
WARNING
Fire Risk
Asphyxiation Risk
Do not draw outside combustion air from:
Wall, fl oor or ceiling cavity.
Enclosed space such as an attic or
garage.
Close proximity to exhaust vents or
chimneys.
Fumes or odor may result.
16
Heatilator • Caliber BV Series • 4040-225 Rev J • 07/06
Remove and discard cover plate from side of appliance.
Open air kit damper slightly.
Install with door hinge toward back of appliance. See
Figure 7.1.
Attach damper assembly to appliance using screws
provided. See Figure 7.2.
Insert narrow end of handle through tab and into upper
slot of door.
Check handle operation. Pull handle out to open, and in
to close.
CAUTION
Risk of Smoke Spillage
Outside air inlet must be located to prevent blockage
from:
• Leaves
• Snow/ice
• Other debris
Blockage may cause combustion air starvation.
Door
Handle
Figure 7.1
Damper Assembly and Handle
Figure 7.2
Outside Air Kit Installation
Hinge
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb4842irCaliber bv series

Table of Contents