Problem solving guide
Water inlet fault
Problem
The buzzer sounds.
One of the following
fault messages appears
in the display:
Water inlet fault
Please open the stopcock
Water intake
The following message
appears in the display
during the
SolarSave
programme:
Intake temp. too low
66
Cause and remedy
The stopcock is closed.
Open the stopcock fully.
Before rectifying the problem:
Switch the dishwasher off using the sensor.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 30
kPa (0.3 bar).
Seek professional advice.
The intake water has not reached the required
temperature of 45°C (see "Plumbing, Connection to
the water supply").
Start the programme again.
If the fault message appears again, select a
different programme.