3.3 SSCNET Cables and Ground Cable

Use our optional SSCNET connection cables.
(1) Cable type
Type
Q172J2BCBL_M(-B)
Q172HBCBL_M(-B)
FR-V5NSCBL_
Q173DVCBL_M
REMARKS
• _ in the type represents the cable length.
Symbol
Cable Length (m)
005
01
05
10
20
• If the necessary length is not found in the optional cables, fabricate it on the customer side. For SSCNET
cables, use the twisted pair shielded cables indicated above or equivalent.
When fabricating a cable, refer to the instruction manual of the motion controller.
The overall wiring length of the bus cables on the same bus is 30m.
(2) Earth (Ground) Cable
For wiring to the earth (ground) terminal of the FR-V5NS, use a crimping terminal with sleeve.
•Cable gause: 2 mm
2
•Crimping terminal: 2-3.5 (with sleeve)
Length [m]
0.5, 1, 5, 10, 20
0.5
1
5
10
20
0.5, 1, 5
UL20276 AWG#28 7 pair (cream)
UL20276 AWG#28 7 pair (ivory)
0.5, 1
UL20276 AWG#28 13 pair (cream)
10
WIRING