10.9 Drain pump

1. PCB
2. Anti-boiling pressure switch
AE2
3. Anti-boiling pressure switch
AE1
4. Drain pump
The PCB powers the drain pump via a triac as follows:
for a pre-determined period.
until the anti-boiling pressure switch closes on EMPTY, after which the pump is actioned for a brief
period or passes to the subsequent phase.

10.10 Recirculation pump

In the Jetsystem models the recirculation pump is powered directly by the main PCB via a triac.
1. PCB
2. Anti-boiling pressure switch AE 2
3. Anti-boiling pressure switch AE 1
4. Recirculation pump
SOI/DT 2005-01 dmm
44/67
599 36 82-57