Husky HDN10500 Operating Instructions Manual page 3

1 inch 23g micro pin nailer
Table of Contents

Advertisement

Available languages

Available languages

Important Safety Instructions
(Continued)
Always remain in a
fi rmly balanced
position when using or handling the
tool.
Avoid long extended
periods of work
with the tool. Stop using the tool if you
feel pain in hands or arms.
TOOL USE AND CARE
a. Use clamps or another practical way
to secure and support the workpiece
to a stable platform. Holding the
work by hand or against the body is
unstable and is able to lead to loss
of control.
b. Do not force the tool. Use the
correct tool for the application. The
correct tool will do the job better
and safer at the rate for which the
tool is designed.
c. Do not use the tool if the switch
does not turn the tool on or off. Any
tool that cannot be controlled with
the switch is dangerous and must be
repaired.
d.
Disconnect the
tool from the air
source before making adjustments,
doing tool maintenance, clearing
jams, leaving work area,loading,
or unloading the tool.
precautionary measures reduce the
risk of injury to persons.
e. Store the tool when it is idle out
of reach of children and other
untrained persons. A tool is
dangerous in the hands of untrained
users.
f. Maintain the tool with care. Keep
a cutting tool sharp and clean. A
properly maintained tool, with sharp
cutting edges reduces the risk of
binding and is easier to control.
g. Check for misalignment or binding
of moving parts, breakage of parts,
and any other condition that affects
the tool's operation. If damaged,
have the tool serviced before using.
Many accidents are caused by poorly
maintained tools. There is a risk of
bursting if the tool is damaged.
h. Use only accessories that are
identified by the manufacturer for
the specific tool model. Use of an
accessory not intended for use with
the specific tool model, increases the
risk of injury to persons.
i. Selecting an appropriate tool
actuation system, taking into
consideration the work application
for which the tool is used.
or other fl ammable liquids
to clean the tool. Never use
the tool in the presence of
fl ammable liquids or gases. Vapors
could ignite by a spark and cause an
explosion which will result in death or
serious personal injury.
Do not remove, tamper
with, or otherwise cause
the trigger lock or trigger
to become inoperable. Do not operate
any tool which has been modifi ed in a
like fashion. Death or serious personal
injury could result.
Do not touch the trigger
unless driving fasteners.
Never attach air line to
tool or carry tool while touching the
trigger. The tool could eject a fastener
Such
which will result in death or serious
personal injury. Also actuate the trigger
lock to the safe position when not in
use.
Always disconnect the
tool from the power
source when unattended,
performing any maintenance or repair,
clearing a jam, or moving the tool to a
new location. Do not load the tool with
fasteners when the trigger is depressed.
The tool could eject a fastener causing
death or serious personal injury.
Always fi t tool with a
fi tting or hose coupling
on or near the tool in
such a manner that all compressed air
in the tool is discharged at the time the
fi tting or hose coupling is disconnected.
Do not use a check valve or any other
fi tting which allows air to remain in the
tool. Death or serious personal injury
could occur.
Never place hands or any
other body parts in the
fastener discharge area of
the tool. The tool might eject a fastener
and could result in death or serious
personal injury.
Never carry the tool by
the air hose or pull the
hose to move the tool
Never use
or a compressor. Keep hoses away from
gasoline
heat, oil and sharp edges. Replace any
hose that is damaged, weak or worn.
Personal injury or tool damage could
occur.
fasteners. Respect the tool as a working
implement; no horseplay. Always keep
others at a safe distance from the work
area in case of accidental discharge of
fasteners. Do not point the tool toward
yourself or anyone whether it contains
fasteners or not. Accidental triggering
of the tool could result in death or
serious personal injury.
Do not drive a fastener
on top of other
fasteners. The fastener
could glance and cause death or a
serious puncture wound.
Do not operate or allow
anyone else to operate
the tool if any warnings
or warning labels are not legible.
Warnings or warning labels are located
on the tool magazine and body.
Dropping or throwing the tool can
result in damage that will make the tool
unusable or unsafe. If the tool has been
dropped or thrown, examine the tool
closely for bent, cracked or broken parts
and air leaks. STOP and repair before
using or serious injury could occur.
magazine is empty. Accelerated wear on
the tool may occur.
and fi ttings before connecting the
tool to an air supply. Replace any
damaged or worn hoses or fi ttings.
Tool performance or durability may be
reduced.
3
HDN10500
Always assume the
tool contains
WARNING
!
Do not drop or
throw the tool.
Avoid using the
tool when the
Clean and check all
air supply hoses

Hide quick links: