Available languages

Existing Construction – accessible from above
C11
Remove an existing fan and check to make sure the
opening is large enough to accommodate the new
motor housing (9"x 9.75").
Cut out an opening for the housing.
C13
5/8
1/2
position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
023_41953_EngS_2-15-08.indd 11
EXISTING FAN
41953-01 02/15/2008
NO EXISTING FAN
OR
Use the motor housing as a template to mark position.
C12
Slide the mounting rails into brackets.
C14
5/8
1/2
Mark position of screws by using holes as a template.
11
F
E
2/16/08 12:25:37 PM