Pre-Installation Check List - Genie 2022 Manual

With 2-bulb light system wall console
Hide thumbs Also See for 2022:
Table of Contents

Advertisement

PRE-INSTALLATION CHECK LIST

Things to consider if you are planning to "Do-it-yourself."
This opener is designed for use with SECTIONAL doors only.
In many cases you will be replacing an existing door opener with a new one, however, if this
will be the first opener installed there are some pre-installation issues which need to be
addressed. They are as follows:
The Genie Company recommends that you read and fully understand all information and
instructions contained herein before choosing a "Do-it-yourself" installation. Any
questions should be directed to The Genie Company or an authorized Genie
( The issue numbers below refer to the circled numbers in the illustrations on page 5.
1
Check your ceiling where the power
head of your new unit will be mounted.
Plan how you will be mounting the power head.
It is possible that ceiling joists may not be in the
position needed with respect to the garage door
opener. It may be necessary to add an
additional bracket and fasteners (not included
with your new door opener kit).
(Refer to Section 2.)
2
Check the wall directly above the garage
.
door
The door opener's header bracket
must be securely fastened to this wall. Insure
that the structure will provide a strong mounting
location. (Refer to Section 2.)
3
Check to see if the mounting location
for the Safe-T-Beam
obstruction and has a wood surface available
for attaching the mounting brackets
brackets may be attached to concrete if necessary
but extra tools and special fasteners (not supplied)
will be required. (Refer to Section 4 and 5.)
NOTE: Mounting brackets must be installed
within code specifications.
4
Is your sectional garage door made of
aluminum, light-weight steel, fiberglass
?
or glass panels
must be added to these type doors. If this is the
case, please contact the door manufacturer or
authorized dealer so that they can furnish you
with a "bracing kit." (Refer to Section 2.)
To reduce the risk of injury to persons or
damage to property - Use this opener only
with sectional doors.
4
System is clear from
®
.
The
Additional support bracing
WARNING
PN# 37026500123
FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM
5
You need a properly grounded 110-120 Volt
power supply available
no more than 3 feet from the power head once it is
mounted. (Refer to Section 5.)
DO NOT USE AN EXTENSION CORD!
DO NOT USE A PORTABLE GENERATOR! This
product is designed to operate on
standard house current.
DO NOT USE ALTERNATE POWER SUPPLIES.
6
To avoid damage to your door and/or
opener, make sure you disable and/or
remove any door locks, ropes, and/or cables
(NOT door lift cables) prior to installing your
. (
opener
Refer to Section 1.)
7
Insure that your door is properly balanced
and moving freely. (Refer to Section 10.)
WARNING
If your door jams, binds, is improperly
balanced or has a broken spring, have it
repaired or adjusted by a trained door system
technician. Door springs, cables, pulleys,
brackets and associated hardware are under
extreme tension and can cause serious injury
or death.
8
(NOT SHOWN) If your garage does not have
a separate entry door, you should consider
an emergency release kit ( GER-2 ) for installation on
your garage door.
05/15/2009
Dealer.
®
)
.
The outlet should be
WARNING
Remove
Remove

Advertisement

Table of Contents
loading

This manual is also suitable for:

20242042

Table of Contents