42Tar018-723 / 38Tar018-723 - Carrier 42CJR024-723 Service Manual

Carrier split wall type air conditioner service manual
Table of Contents

Advertisement

5-4. 42TAR018-723 / 38TAR018-723

0.39 m
(Connecting pipe)
∅15.88
O.D.:15.88 mm
P
Packed valve
Accumulator
PH290X2C-4FT1
Compressor
50 Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Cross flow fan
(∅15.88)
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.5
0.6
0.3
T
Indoor unit
Evaporator
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
12.0
2.0
– 24 –
FILE NO. SVM-05010
0.49 m
(Connecting pipe)
∅6.35
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0 x 800 s
Refrigerant
R22 1.47 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15

Hide quick links: