Outdoor Unit (38Cjr024-723, 38Tar024X-723); Outdoor Unit (38Cjr018-723) - Carrier 42CJR024-723 Service Manual

Carrier split wall type air conditioner service manual
Table of Contents

Advertisement

4-3. Outdoor Unit (38CJR024-723, 38TAR024X-723)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-4. Outdoor Unit (38CJR018-723)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 - 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω )
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 - 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(at 20 °C
451355L
AC 450 V, 3.5µ F
AC 440 V, 45 µF
BUM44X4505B
A35
220
- 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH340X3C-4KT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
WLF-240-42A-1
Winding resistance (Ω)
(at 20°C)
451155L
AC 450 V, 1.5µF
BUM44X4505B
AC 440 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
– 18 –
FILE NO. SVM-05010
Specifications
C-R
1.13
Red-Black
64.4
Specifications
C-R
1.46
Red-Black
White-Black
188
C-S
2.10
White-Black
127.4
C-S
2.47
289