Specification Of Electrical Parts; Indoor Unit (42Cjr024-723, 42Cjr018-723, 42Tar024X-723, 42Tar018-723); Indoor Unit (42Hnr024-713, 42Hnr018-713) - Carrier 42CJR024-723 Service Manual

Carrier split wall type air conditioner service manual
Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (42CJR024-723, 42CJR018-723, 42TAR024X-723, 42TAR018-723)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Module (M01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
13
Relay : (RY04)

4-2. Indoor Unit (42HNR024-713, 42HNR018-713)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro Power Model (M01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
Type
AFS-220-31A
———
µRM1260V
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
BET6.3A
15G561K
RF-2TK5R6
MP35EA12
G5NB-1A
Type
AFS-220-31A
———
µ
RW1260 V
TMP87CM40AN
———
LC*SS11V-06270
D3SBA60
KMN400VSSN47M22S
BET6.3A
15G561K
RF-2TK5R6
MP35EA12
– 17 –
FILE NO. SVM-05010
Specifications
AC 200 − 240V, 31W
10 kΩ at 25°C
DC 390 V, Secondary DC 12 V
10 kΩ at 25°C
27mH, 600mA
4 A, 600 V
4.7µF, 400 V
T6.3 A, 250 V
560 V
5.6Ω , 2 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Coil DC 12V, 16.7mA, Contact AC 250V, 1A
Specifications
AC 200 V, 31 W
10 kΩ at 25°C
DC 390 V, Secondary DC 12 V
10 kΩ at 25°C
27 mH, 600mA
4 A, 600 V
4.74µF, 400 V
T6.3A, 250 V
560 V
5.6 Ω, 2 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V

Hide quick links: