4-5. Outdoor Unit (38TAR018-723)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor

4-6. Outdoor Unit (38HNR024-713)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74, R86)
11
Fuse (F01)
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH290X2C-4FT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(at 20°C)
451355L
AC 440 V, 3.5µF
BUM44X3505A
AC 440 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
2JS386D5BB02
Winding resistance ( Ω )
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
KFG6-71SB5P-T1 Winding resistance (Ω)
(at 20°C)
451355L
AC 450 V, 3.5µF
BUM44X6005C
AC 440 V, 60µF
VHV (STF)
AC 220 − 240 V
TE / TD
10 k Ω at 25°C / 50 kΩ at 25°C
A35
220 − 240 V, 50 Hz
TT-05
220 − 240 V
TMP47C840N
15G471K
470 V
MT3
T6.3 A, 250 V
– 19 –
FILE NO. SVM-05010
Specifications
C-R
1.71
Red-Black
White-Black
64.4
Specifications
C-R
0.886
Red-Black
White-Black
64.4
C-S
3.09
127.4
C-S
1.979
127.4