Electrical Connections - Biasi RIVA ADVANCE HE M110.24SM User Manual And Installation Instructions

Wall hung, fan flue, room sealed, high efficiency gas boiler
Table of Contents

Advertisement

Installation
either pipe must be reduced by 0.90 m or 1,65 m
respectively.
Referring to Fig. 6.6, the minimum length required
for pipes a and b is 0.3 m.
Maximum equivalent length "a+b" of 40 metres
can be achieved utilising extensions.
Fig. 6.6
Vertical--- roof kit (Fig. 6.7)
Co--- axial 80/125 mm
This kit allows vertical termination of the flue pipe
through the roof. The kit is 1.2 min length. Exten-
sion pieces (Co--- axial) are also available which al-
lows the flue system to be extended to a total
overall maximum permissible length of 10 m.
Optional 45û and 90û elbows can be used to offset
the flue route.
Each additional elbow reduces the overall accept-
able length of the flue system as follows:
45û reduce length by 0.5 m.
90û reduce length by 1 m.
max = 10 m
Fig. 6.7
26
6.9
Connection to the electricity supply
1 Remove the front panel of the case (see the
2 Remove the screws I and J (Fig. 6.8).
3 Loosen the screws K.
90û=--- 1,65 m
45û=--- 0,90 m
J
Fig. 6.8
4 Remove the side panels or move the lower part
90û=--- 1m
45û=--- 0,5m
Fig. 6.9
5 Loosen the screws L and remove the service

Electrical connections

section 8.2 in this manual).
K
of the side panels as indicated in Fig. 6.9 and
pull the control panel.
When completely pulled out, the panel can ro-
tate 45û downwards to facilitate the operations
on the internal parts.
panel (Fig. 6.10).
I
J