Review With Owner; Oiled Bearing Circulators - A.O. Smith 400 - 2100 Installation & Operation Manual

Genesis water heater
Table of Contents

Advertisement

9
Maintenance
Inspect and clean the heat exchanger
1.
While burners are removed, check the heat exchanger
surface for sooting. If present, heat exchanger must be
cleaned and problem corrected. Proceed as follows.
2.
Remove gas manifold(s)/orifice assemblies as described
in steps 1 through 5 in Inspect and Clean Burner, page 64.
3.
Disconnect wiring from the hot surface igniter and
hose from the burner pressure tap.
4.
Remove inner jacket panel mounting screws and slide
door assembly out toward front of the unit. Use
caution to prevent damage to the refractory and hot
surface igniter.
5.
Check "V" baffles and frame runners along front
and back edges of heat exchanger. Remove and clean if
necessary.
6.
Remove soot from heat exchanger with a stiff bristle
brush. Use a vacuum to remove loose soot from
surfaces and inner chamber.
7.
The heat exchanger can be removed by sliding towards
the front of the unit. Once the heat exchanger is
removed from the unit, a garden hose can be used
to wash the tubes to ensure that all soot is removed
from the heat exchanger surfaces. Note: Do not wet the
unit's refractory.
8.
Ensure that all burner ports are cleaned to remove any
soot. See Inspect and Clean Burner, page 64.
9.
Carefully reinstall the heat exchanger, "V" baffles, and
frame runners if removed from the unit. Note: Make
sure frame runners seal securely where they contact the
front and rear compartment refractory.
10. Carefully
reinstall
manifolds, wires and hoses. Use new gasket material to
ensure a proper air seal.
11. Reassemble all gas and water piping. Test for gas leaks.
Upon completion of any testing on the gas
NOTICE
system, leak test all gas connections with a
soap and water solution while main burners
are operating. Do not spray soap and water
solution on the control module housing.
The use of an excessive amount of soap
and water solution can damage the control.
Immediately repair any leak found in the
gas train or related components. Do not
operate an appliance with a leak in the gas
train, valves, or related piping.
12. Reassemble outer jacket panels.
13. Cycle unit and check for proper operation.
(continued)
inner
jacket
panels,
burners,
Installation & Operation Manual
HEAT
EXCHANGER
Figure 9-3_Location of the Heat Exchanger Inside
Jacket

Review with owner

1. Emphasize the need to perform the maintenance schedule
specified in this section.
2. Remind the owner of the need to call a licensed contractor
should the appliance or system exhibit any unusual behavior.
3. Remind the owner to follow the proper shutdown procedure
and to schedule an annual start-up at the beginning of the
next heating season.

Oiled bearing circulators

Inspect the pump every six (6) months and oil as necessary. Use
SAE 30 non-detergent oil or lubricant specified by the pump
manufacturer.
IMG00601
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents