2.
Remove outer case.
3.
Remove the complete control panel as-
sembly.
4.
Remove the upper halogen blower/lamp
assembly.
5.
Remove the 6 screws securing the relay
board/air guide cover assembly to the
oven chassis (see illustration below).
RELAY BOARD/AIR GUIDE
COVER ASSEMBLY REMOVED
6.
Swing the relay board/air guide assembly
away from the unit so that you can ac-
cess the magnetron blower assembly.
7.
Remove the wiring connector plug from
the magnetron blower motor and remove
all associated wiring from the magnetron
B
HIGH VOLTAGE WIRES:
RED WIRE W/BLACK
B
STRIPES PLUS WHITE
WIRE
A
A
A
B
8.
DAMPER DOOR ASSEMBLY - REMOVAL
To remove the damper door assembly, follow
these steps:
1.
2.
– 42 –
blower housing (see illustration to the up-
per right). Important note: Be sure to
note the location and routing of wires for
proper reinstallation purposes.
LOWER HALOGEN BLOWER/MAG.
MOTOR WIRING HARNESS
HIGH VOLTAGE WIRE:
RED WIRE W/ BLACK STRIPS
Remove one screw securing the magne-
tron blower assembly to the oven chas-
sis, (see illustration below), and remove
the blower assembly.
MAGNETRON
BLOWER ASSY
Remove the oven from the wall plate
Remove the outer case