To remove the outer case, first remove the power
cord cover plate.
Remove two screws from the bottom hood cover
which secure the hood cover to the outer case.
B
Remove 11 screws shown below.
FRONT GRILLE
MOUNTING SCREWS
A
A
A
B
B
Remove 11 screws and release side cabinet panels
from between oven chassis and vent hood.
B
B
A
A
A
B
B
B
Lift off the outer case, feeding the power cord
through the opening in the top of the case.
UPPER HALOGEN BLOWER/LAMP ASSEM-
BLY REMOVAL
With the outer case removed, you now have ac-
cess to the humidity sensor and cavity TCO.
CAVITY
TCO
HUMIDITY
SENSOR
To replace the upper halogen lamp pair, halogen
lamp thermal cut outs, or upper halogen blower
assembly, the complete halogen blower/lamp
assembly must first be removed:
1.
Remove the vent motor and the vent mo-
tor heat shield (see illustration on next
page).
move the complete outer case to change
or remove the vent motor (see installation
instructions for additional information).
2.
Remove the vent motor connector plug
from the blower housing assembly (see
photo on next page).
3.
Disconnect the high voltage transformer
leads from the high voltage capacitor.
CAUTION
high voltage capacitor prior to servicing.
Note the location of the red and white wire
– 39 –
Note: it is not necessary to re-
Be sure to discharge the

Hide quick links: