3. Draw a vertical line on the wall at the center
of the 30" wide space.
Use the mounting plate as the template for
the rear wall. Place the mounting plate on the
wall, making sure that the tabs are against the
bottom of the cabinet. Line up the notch and
center line on the mounting plate to the
center line on the wall.
Minimum 66"
From the Floor
Mounting
Plate
A
Center Line
C
Tab
3/16 " Hole on Studs
5/8 " Hole on Drywall Only
For Outside
Back Exhaust
Only
Draw Lines
on Studs
Draw
Center Line
B
D
E
Tab
4. While holding the mounting plate with one
hand, draw circles on the wall at holes A, B,
C and D. Four holes must be used for
mounting. If the holes are not used, the
installation will not be secure. Installer
must use these holes for proper
installation. Use toggle bolts through these
holes unless one of them lines up with a stud.
Use a wood screw for studs.
NOTE: Draw a fifth circle inside area E, through
one of the bottom holes to match the location
of a stud.
For outside back exhaust: The oven requires
a rear wall cutout opening for the rear wall duct
and the exhaust adaptor must be attached to
the mounting plate. See the next page on how to
prepare the rear wall cutout opening and the
exhaust adaptor/mounting plate for outside
back exhaust.
Set the mounting plate aside.
5. Drill holes on the circles. If there is a stud, drill
a 3/16" hole for wood screws. If there is no
stud, drill a 5/8" hole for toggle bolts. Make
sure to use at least 1 wood screw in a
stud, and 4 toggle bolts in the dr ywall or
the plaster.
6. Attach the plate to the wall. To use toggle
bolts: Remove the toggle wings from the
bolts. Insert the bolts into the mounting plate
and replace the toggle wings to 3/4" past the
bolt ends. Insert the toggle wings into the
holes in the wall to mount the bracket. You
may pull forward on the bracket to help in
tightening the toggle bolts. Tighten all bolts.
Mounting
Plate
– 11 –
Space More Than Wall Thickness
Toggle Wings
Toggle Bolt
Wall
Bolt
End