Finishing; Mantel Projections; Section 11: Finishing A. Mantel Projections; Facing Material - Heat & Glo 6000GL-IPI-R Owner's Manual

Hide thumbs Also See for 6000GL-IPI-R:
Table of Contents

Advertisement

11

Finishing

A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding maxi-
mum horizontal dimensions of appliance mantels or other com-
bustible projections above the top front edge of the appliance.
Note: All
measurements
in inches.
4
3
2-1/2
5
NOTE: Measurement is taken from top of the
opening, NOT the top of the fi replace.
Figure 11.1
Clearances to Mantels or other Combustibles
above Appliance
Top View
A
FIREPLACE
OPENING
MANTEL LEG OR WALL PROJECTIONS
A
If
minimum is ____, then
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Inches
A
62
Millimeters
1
Inches
B
25
Millimeters
Figure 11.2
Mantel Leg or Wall Projections
(Acceptable on both sides of opening.)
B.

Facing Material

WARNING
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and fi re hazard.
Finishing materials must not interfere with:
Air fl ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
38
TO CEILING
18
12
11
10
32
9
8
25
7
19
6
18
5
17
16
15
14
13
12
11
10
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
INTERIOR WALL
B
B
maximum is_____.
87
113
138
164
189
2
3
4
5
51
76
102
127
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. B • 5/06
NON-COMBUSTIBLE ZONE (Shaded areas)
41 in.
Figure 11.3 Noncombustible Facing
WARNING
Risk of Fire
Non-combustible clearances MUST be
maintained.
Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
See Section 11 for proper clearances.
See Section 1 for combustible/non-
combustible defi nitions.
WARNING
Fire Risk.
Finish all edges and fronts to clearances and
specifi cations listed in manual.
Black metal appliance front may be covered with
noncombustible material only.
Do NOT overlap combustible materials onto appliance
front.
Install combustible materials only up to specifi ed clear-
ances on top, front and side.
Seal joints between the fi nished wall and appliance top
and sides using only a 300
39-3/8 in.
o
F minimum sealant.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000gl-ipi-s6000gl-ipilp-r6000gl-ipilp-s

Table of Contents