Installing Dimms - HP PROLIANT ML330 G6 User Manual

Hewlett-packard server user manual
Hide thumbs Also See for PROLIANT ML330 G6:
Table of Contents

Advertisement

Next: D, E, and F
o
Last: G, H, and I
o
UDIMM
First: A, B, and C
o
Last: D, E, and F
o
Do not populate slots G, H, and I.
o
After installing the DIMMs, use RBSU to configure the system for online spare memory support
("Configuring online spare
Multi-processor Online Spare population order
For Online Spare mode configurations with a multiple processors, populate the DIMM slots for each
processor in the following order:
RDIMM
First: A, B, and C
o
Next: D, E, and F
o
Last: G, H, and I
o
UDIMM
First: A, B, and C
o
Last: D, E, and F
o
Do not populate slots G, H, and I.
o
After installing the DIMMs, use RBSU to configure the system for online spare memory support
("Configuring online spare

Installing DIMMs

CAUTION:
air baffle, drive blanks, and access panel must be installed when the server is powered up.
Power down the server (on page 20).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
o
Extend the server from the rack (on page 21).
o
Remove the access panel (on page 21).
3.
Remove the air baffle (on page 22).
4.
Open the DIMM slot latches.
5.
memory" on page 87).
memory" on page 87).
To avoid damage to the hard drives, memory, and other system components, the
("Open or remove the tower
Hardware options installation 47
bezel" on page 20).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents