Adjusting The Burn Rate; Ash Removal - Lopi Freedom Bay Fireplace Insert Owner's Manual

Masonry fireplace insert
Hide thumbs Also See for Freedom Bay Fireplace Insert:
Table of Contents

Advertisement

Adjusting the Burn Rate

Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Use the air control to
change the burn rate.
Low Burn
(air control closed)
Approximate Air Control Settings:
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.

Ash Removal

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
ASHES
dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled.
© Travis Industries
Operating Your Appliance
High Burn
(air control open)
Overnight Burn
Medium Burn
Medium High Burn
High Burn
100-01163
Fully out to 9/32" (8mm) open
9/32" (8mm) to 5/16" (4mm) open
5/16" (4mm) to 7/16" (6mm) open
7/16" (6mm) open to fully pushed in
17
4041129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom bay nd

Table of Contents