Hot and cold water faucets:
Must
be within 4 feet of the back of the
washer and provide
water pressure
5-100 PSI.
Laundry tub drain system:
Needs a
20-gallon
laundry
tub. Top of tub
must be at least 34 inches high and
no higher than 72 inches from
bottom
of washer.
Before you
start...
Untape
and open washer lid. Remove
packages
and hoses from washer.
Check
location
where washer
will be installed.
Proper
installation
is your responsibility.
Make sure you have everything
necessary
for correct
installation.
Grounded
electrical
outlet is
required.
See Electrical
requirements.
Standpipe
drain system:
Needs
a two-inch
minimum
diameter
standpipe
with minimum
carry-away
capacity
of
17 gallons per
minute.
Top of
standpipe
must 4
be at least 34
inches high and
no higher than
72 inches from
bottom
of
washer.
I
'
i
If a longer drain hose is ne/eded,
drain hose (Part No. 388423) and
hose extension
kit (Part No. 285442)
are available
from authorized
parts
distributors.
If drain hose must be
El
shortene d, use kit (Part No. 285442).
Important:
Observe
all governing
codes and ordinances.
Floor drain
system requires
a siphon break,
Part No. 285320.
ater heater:
Set
to deliver
140°F
water to washer.
Product
Damage
Do Not store or operate
washer below 32°F (some
water may remain
in
washer).
See Use & Care Guide for
"Winterizing"
Information.
Failure to follow above
may
result in product
damage.
SEE
Support:
Floor must be sturdy enough
to
support
washer weight
of 3 15 pounds.
Electrical
Recommended
reqllirements
grounding method
INSTRUCTIONS ON
BACK COVER.
For your personal
safety, this appliance
must be grounded.
This appliance
is
equipped
with a power supply cord
having
a 3-prong
grounding
plug.
To
minimize
possible shock hazard,
the cord
must be plugged
into a mating
3-prong
grounding-type
wall receptacle,
grounded
in accordance
with National
Electrical
Code, ANSI/NT-PA 70-latest
edition
and all local codes and
ordinances.
See Figure 1. If a mating
wall receptacle
is not available,
it is the
personal
responsibility
and obligation
of
the customer
to have a properly
grounded
S-prong wall receptacle
installed
by a qualified
electrician.
Tools needed for
installation:
Electrical
Shock Hazard
l
Electrical
ground
is required
on this
appliance.
l
If cold water pipe is interrupted
by
plastic,
non-metallic
gaskets or other
insulating
materials,
Do Not use for
grounding.
. Do Not ground
to a gas pipe.
l
Do Not modify
the power supply
cord plug. If it does not fit the outlet,
have a proper outlet installed
by a
qualified
electrician.
l
Do Not have a fuse in the neutral
or
grounding
circuit.
A fuse in the
neutral or grounding
circuit
could
result in an electrical
shock.
. Do Not use an extension
cord with
this appliance.
l
Check
with a qualified
electrician
if
you are in doubt as to whether
the
appliance
is properly
grounded.
Failure to follow these instructions
could
result in serious injury or death.
Parts supplied for
installation:
J-prong
grounding-
type wall
receptacle
If codes permit and a separate
grounding
wire is used, it is recommended
that a
qualified
electrician
determine
that the
grounding
path is adequate.
120-Volt, 60-Hz, AC-only,
15- or 20-
ampere
fused electrical
supply is
required.
(Time-delay
fuse or circuit
breaker
is recommended,)
It is
recommended
that a separate
circuit
serving only this appliance
be provided.
Remove
parts from packages.
Check
that all parts were included.
Figure 1
1 small clamp
literature
package
1 drain hose
1 hose clamp
2 inlet hoses
4 flat water hose
washers
2 front leveling
legs
with nuts
Panel A