Shifting The Range - Furuno FCV-1150 Operator's Manual

Color lcd sounder
Hide thumbs Also See for FCV-1150:
Table of Contents

Advertisement

1. OPERATION
2. Rotate the RANGE control to select a
range. The default ranges are as shown
in the table.
Unit
Basic Range No, Range
1
m
10
ft
30
fa
5
HR*
6
pb
6
5
m
150
300
ft
500
1000
fa
80
160
HR*
100
200
pb
100
200
* HR is Hiro, Japanese unit of depth mea-
surement.
3. Press the ENTER key.
Note 1: Basic ranges may be preset as de-
sired, on the Range menu.
Note 2: The range mode indication (AUTO or
MANUAL), which appears at the top-left cor-
ner, may be turned on or off with Header Info
in the Display menu.
Note 3: In the dual frequency display, the
range for the low and high frequencies can be
adjusted mutually or independently. Turn on
Split Range in the Range menu to enable in-
dependent adjustment.
2
3
4
20
40
80
60
120
250
10
20
40
12
25
50
12
25
50
6
7
8
500
1000
1600
3000
250
600
300
600
300
600
1.6

Shifting the Range

The basic range and range shifting functions
used together give you the means to select
the depth you can see on the screen. The ba-
sic range can be thought of as providing a
"window" into the water column and range
shifting as moving the "window" to the desired
depth.
Window can be
shifted up and
down to select
starting depth.
Note: This function is inoperative when the
Auto mode is active.
1. Press
or
the Shift setting window.
2. Use
or
on the SHIFT key to select
the amount of shift desired.
3. Press the MENU/ESC key to close the
window, or wait six seconds to automati-
cally close it.
Note 1: The bottom echo may be lost if the
amount of shift is greater than actual depth.
Note 2: "Auto Shift," which can be turned on
from the Sounder menu, automatically shifts
the range to keep the bottom echo on the
screen.
Note 3: You can set the shift value for each
range independently, by turning on Free Shift
in the Sounder menu.
6
Display
on the SHIFT key to show

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents