Page 1
SIK 7 TE SIK 9 TE SIK 11 TE Montage- und SIK 14 TE Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Sole/Wasser- Brine-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for eau glycolée-eau Innenaufstellung Indoor Installation pour installation intérieure...
Please Read 1.2 Legal Regulations and Immediately Directives This heat pump conforms to all relevant DIN/VDE regulations and EU directives. Refer to the EC Declaration of Conformity in 1.1 Important Information the appendix for details. The heat pump must be connected to the power supply in com- ATTENTION! pliance with all relevant VDE, EN and IEC standards.
The refrigerant subsequently passes through the liquifier where it transfers its thermal energy to the heating water. Depending on the set operating point (thermostat setting), the heating water is thus heated up to a max. of 60 °C. Control panel Circulating pumps Liquifier Compressor Evaporator Expansion vessel www.dimplex.de...
Accessories Set-up 4.1 Brine Circuit Manifold 6.1 General Information The brine circuit manifold merges the individual collector loops of The unit must be installed indoors on a level, smooth and hori- the heat source system into a single main pipe which is con- zontal surface.
The heat source system must be de-aerated and checked for leaks. ATTENTION! The brine solution must contain at least a 25 % concentration of a monoethylene glycol or propylene glycol-based antifreeze, which must be mixed before filling. www.dimplex.de...
7.4 Electrical Connection 8.2 Preparation The following electrical connections need to be established on The following items need to be checked prior to start-up: the heat pump. The heat pump must be fully connected, as described in The mains cable must be connected to the control panel of Chapter 7.
Clean the dirt trap’s filter screen one day after start-up and sub- sequently in weekly intervals. If no more signs of contamination are evident, the filter can be removed to reduce pressure drops. www.dimplex.de...
12 Device Information Type and order code SIK 7TE SIK 9TE SIK 11TE SIK 14TE Design Model Compact Compact Compact Compact Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 Installation Location Indoors Indoors Indoors Indoors...
3.4 Legende / Legend / Légende Drahtbrücke, muss eingelegt werden, wenn kein Wire jumper, must be inserted if no utility blocking Cavalier à fil à monter si aucun contacteur de cou- EVU-Sperrschütz benötigt wird contactor is required pure du fournisseur d'énergie n'est requis Drahtbrücke, muss bei Verwendung des 2ten Sper- Wire jumper, must be removed if the 2nd disable Cavalier à...
5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité www.dimplex.de A-XIII...
Page 23
Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...