Water inlet fault
Problem
All in-operation indica‐
tors are flashing quick‐
ly.
The warning buzzer is
sounding.
One of the following
faults is shown in the
display:
Water inlet fault. Please
open the stopcock
Water inlet fault
The following message
appears in the display
during the
SolarSave
gramme:
Water in. temp. too low
Cause and remedy
The stopcock is closed.
Open the stopcock fully.
Before rectifying the problem:
Switch the dishwasher off using the sensor.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 30
kPa (0.3 bar).
Seek professional advice.
The intake water has not reached the required tem‐
perature of 45°C (see "Plumbing, Connection to the
pro‐
water supply").
Start the programme again.
If the fault message appears again, select a differ‐
ent programme.
Problem solving guide