Gemini GEM-DXK2 Operating Manual page 31

Gemini keypad
Table of Contents

Advertisement

T R O U B L E
S YSTBL
A C O N
T R O U B L E
E01 -00/
ACF AI L
A C O N
T R O U B L E
E02 -00/
LOBATT
A C O N
T R O U B L E
E03 -00/
COMM FL
A C O N
T R O U B L E
E06 -01
A C O N
OV(RR)
A C O N
EntNow
A C O N
K E Y P AD M E S S AG E S
Indicates problem(s) detected on the system (see below).
Check power transformer. Check for blown fuse or circuit breaker; general power outage.
Battery weak. If not recharged within 24 hours, replace battery.
Communication failure to central station.
(Wireless systems only). Receiver response failure, Receiver No. 1. The following addi-
tional wireless messages may also appear:
"E04-01" - Supervisory trouble on Zone 1 (transmitter has not "checked in").
"E05-01" - Transmitter on Zone 1 has a low battery;
"E15-01" - Transmitter on Zone 1 has its case open (tamper condition);
(OPTIONAL) (Commercial Systems Only). Overview Mode. Simultaneously shows
status of Areas 1 and 2. "R" Area Ready; "Z" Zone Fault; 'A" = Area Armed; "B" = Bur-
glary Zone in Alarm; "F" = Fire Zone in Alarm; "T" = Fire Trouble; "c" = Check Trouble;
Area in Function-Display Mode.
(Commercial Systems Only). Remote-access keypad unlocked for 5 seconds to allow
entry.