Figure 3-8 Installation Scenario C Using The Ves-1012 - ZyXEL Communications VES-1008 Hardware Installation Manual

Ves-1000 series vdsl-ethernet switches
Hide thumbs Also See for VES-1008:
Table of Contents

Advertisement

VES-1000 Series Ethernet Switch
Procedure To Connect To MDFs
Acquire two additional MDFs (3 and 4).
Step 1.
For the VES-1008 only, follow the pin assignments shown in Diagram 5 to configure a cable for this
Step 2.
installation.
For the VES-1012 only, follow the pin assignments shown in the Diagram 6 and Diagram 7 to wire two
Telco cables (not supplied in the package) to two Telco-50 connectors (supplied).
For the VES-1008 only, when configured, connect the Telco-50 connector to the combined USER/CO
Step 3.
Telco-50 port located on the front panel of the VES-1008.
For the VES-1012 only, connect the Telco-50 connector end of the Telco cable you want for VDSL
service to the Telco-50 port labeled USER on the VES-1012 front panel.
Connect the wiring on the other side of the Telco-50 cable to the upper ports of MDF 3 using a punch-
Step 4.
down tool.
Connect the lower ports of MDF 3 to the upper ports of MDF 2 for those users that want VDSL service.
Step 5.
(Users who want to telephone service only, retain the original connection from the top port of MDF 2 to
the bottom port of MDF 1.)
Connect the telephone wiring from the end-user's VDSL equipment to the lower ports of MDF 2.
Step 6.
For the VES-1012 only, for voice service, connect the Telco-50 connector end of the Telco cable you
Step 7.
want for voice service to the Telco-50 port labeled CO on the VES-1012 front panel.
3-8

Figure 3-8 Installation Scenario C using the VES-1012

Installation Scenarios