Figure 2-3 Attaching the Wall-mounting brackets to the VES-1008

Using a #2 Philips screwdriver, install the M3 flat head screws that came with the brackets through the
Step 2.
mounting bracket holes into the VES-1008.
Repeat Step 1 and Step 2 to install the second mounting bracket on the other side of the unit.
Step 3.
You may now mount the VES-1008 on the wall.
Position the VES-1008 flat against the wall and screw the mounting brackets directly to the wall. Make
Step 4.
certain that at least one of the mounting brackets is screwed into an upright beam, or stud, that is located
within the wall. This ensures that the combined weight of the VES-1008 and the cables will not force
any extra pressure on the actual wall.
Plug the Telco-50 cable and the power supply into the unit and make certain that all cables are safely
Step 5.
positioned and that you are able to easily monitor and observe the LEDs.

2.3 Installing the VES-1012

2.3.1

Free-standing

Position the VES-1012 on a flat surface. Make certain that nothing obstructs the cooling fans and that the unit has
adequate ventilation.