Duerkopp Adler 650-16 Service Instructions Manual page 59

Table of Contents

Advertisement

Service settings via software
Directly after entering the code, the display shows the 4 menu items for
technician level:
• Default Program
• Machine config.
• User config.
• Service
Access after an error message
After some error messages it may be impossible to access menus or pro-
grams. Even after switching the machine off and back on, the machine
boots with an error message and does not continue into the programs.
For this case, there is the option of sending the machine to technician
mode directly on booting, in order to perform
of issuing a
Operating steps
1. Switch off the machine at the main switch.
2. Hold down the
3. Enter the technician code 25483 ( Chap. 18.2, p. 56).
Service Instructions 650-16 Version 00.0 - Last Updated 09/2012
Presets for new programs to be created
Start and end tack, thread trimmer, speeds, stop positions, sewing foot
lifting
Audible signal between program steps, left pedal function, program
cancel with pedal, change between right and left sleeve
Test functions for solenoids and drives, calibration of transport, sewing
feet and thread tension, reset functions
Reset all
key and switch on the machine at the main switch.
F
The machine boots and the display shows the input mask for the
code.
Only the two submenus
: Tests for error diagnostics ( p. 63)
Multitest
: Reset the machine to the factory defaults ( p. 72)
Reset all
Multitest
to restore the factory defaults.
and
Multitest
diagnostics or
are available.
Reset
57