Storage Procedure - Honda EG3500X Owner's Manual

Generator
Hide thumbs Also See for EG3500X:
Table of Contents

Advertisement

Storage Procedure
1. Drain the carburetor by loosening the draik screw. Drain the gasoline
into a suitable container.
Gasoline
is extremely
flammable
and 'is explosive
under certain
conditions
Perform this task in a well ventilated area with the engine
stopped. Do not smoke or allow flames or sparks in the area during this
procedure.
DRAIN SCREW
2. Change the engine oil (page 26).
3. Remove the spark plug, and pour about a tablespoon of clean engine oil
into the cylinder. Crank the engine several revolutions to distribute the oil,
then reinstall the spark plug.
4. Slowly pull the starter grip until resistance is felt. At this point, the piston
is coming up on its compression
stroke and both the intake and exhaust
valves are closed. Storing the engine in this position will help to protect it
from internal corrosion.
gn the notch on the starter pulley
with the hole at the top of recoil starter.