Storage Procedure - Honda EU 1000i Owner's Manual

Honda generator owner's manual
Hide thumbs Also See for EU 1000i:
Table of Contents

Advertisement

Storage Procedure

1.
Drain the gasoline.
a.
Remove the fuel tank cap, and empty the fuel tank into an approved
gasoline container using a commercially available hand siphon. Reinstall
the fuel tank cap.
b.
Loosen the cover screw and remove the left-side maintenance cover.
c.
Loosen the carburetor drain screw.
d.
Drain the gasoline from the carburetor into a suitable container.
e.
Remove the spark plug maintenance cover.
f.
Remove the spark plug cap.
g.
Turn the engine switch to the ON position.
h.
Pull the starter grip 3 to 4 times to drain the gasoline from the fuel pump
into a suitable container.
i.
Turn the engine switch to the OFF position.
j.
Tighten the carburetor drain screw.
Gasoline is highly flammable and explosive. You can be burned or
seriously injured when handling fuel.
Keep heat, sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
DRAIN SCREW