New York City Approval - Superior SSDVST-CNM Installation Instructions Manual

Direct vent multi-open series
Table of Contents

Advertisement

These fi replaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have
an alternate heat source when installed in a
dwelling.
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter
(piezo) that allows the appliance's pilot gas to
be lit without the use of matches or batteries.
This system provides continued service in the
event of a power outage.
Millivolt models come standard with a manu-
ally-modulated gas valve; fl ame appearance and
heat output can be controlled at the gas valve.
The BTU Input for these appliances is shown
in Table 1.
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
Models
Fuel Type
Natural or
SSDVST
Propane Gas
SSDVPF
Table 1
Electronic Models - Electronic models have
a fi xed rate gas valve. The BTU input for the
electronic models is shown in Table 2.
BTU Input - Electronic Models
Input (BTU) - Fixed Rate
(electronic models)
Models
Fuel Type
Natural or
SSDVST
Propane Gas
SSDVPF
Table 2
Gas Pressure - All Models
Tables 3, 4 and 5 show the appliances' gas
pressure requirements:
Inlet Gas Supply Pressure
(all models)
Fuel #
Minimum
5.0" WC
Natural Gas
(1.24 kPa)
11.0" WC
Propane
(2.74 kPa)
Table 3
Manifold Gas Supply Pressure
Fuel #
Natural
Gas
Propane
Table 4
Manifold Gas Supply Pressure
Fuel #
Natural Gas
Propane
Table 5
Input Rate
(BTU / HR)
Test gauge connections are provided on the
front of the millivolt gas control valve, identi-
37,500 high
fi ed IN for the inlet and OUT for the manifold
30,000 low
side. A 1/8" NPT Test gauge connection
is provided at the inlet and outlet side of
the electronic gas control valve.
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3.5 kPa).
Input Rate
These appliances and their individual shut-
(BTU / HR)
off valves must be disconnected from the
gas supply piping system during any pres-
37,500
sure testing of that system at pressures
greater than 1/2 psig (3.5 kPa).
Orifi ce Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 6). For
elevations above 4500 feet, contact your gas
Maximum
supplier or qualifi ed service technician . Install
10.5" WC
the appliance according to the regulations of
(2.61 kPa)
the local authorities having jurisdiction and, in
the USA, the National Fuel Gas Code NFPA 54
13.0" WC
/ ANSI Z223.1 - latest edition or, in Canada, the
(3.23 kPa)
CAN1-B149.1 and .2 codes - latest edition.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
(millivolt models)
Low
High
(Lo) 2.2" WC
(Hi) 3.5" WC
(.55 kPa)
(.87 kPa)
(Lo) 6.3" WC
(Hi) 10.0" WC
(1.57 kPa)
(2.49 kPa)
(electronic models)
Maximum Manifold Pres-
sure
(Hi) 3.5" WC (.87 kPa)
(Hi) 10.0" WC (2.49 kPa)
Burner Orifi ce Sizes (all models)
• •
Elevation
Natural Gas
Feet (meters)
drill size (inches)
0-4500
#44 (.086")
*
(0-1372)
60J8001 •
* Standard size installed at factory
• Part /Cat. Number
Table 6
• • Each model has two burners & 2 Orifi ces
Gas Valve Diagrams - See Figure 1 for Millivolt
models and Figure 2 For Electronic Models.
SIT Millivolt Gas Valve
HI/LO Variable
Inlet Pressure Tap
Flame Height
Adjustment
Manifold Pressure Tap
Main Gas Control Knob
Pilot Adjustment
Screw
OFF/PILOT/ON
Figure 1
Honeywell Electronic Gas Valve
Manifold Pressure
ON / OFF Switch
Port
Electronic Gas
Control Valve
Figure 2
New York City, New York (MEA)
Installation of these fi replaces are approved
for installation in New York City in the US state
of New York.
Propane Gas
drill size (inches)
#55 (.052")
*
19L5201 •
Inlet
Pressure
Port
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssdvst-cneSsdvpf-cnmSsdvpf-cne

Table of Contents