FIREPLACE SPECIFICATIONS - SSDVPF (PENINSULA VIEW)
SPECIFICATIONS
Natural & Propane
Gas BTU Input
Co-axial DV Vent Size
NOTES
Annual Fuel Utilization Effi ciency
Due to Lennox' ongoing commitment to quality,
all specifi cations, ratings and dimensions are
subject to change without notice.
Appliance has a factory-installed vent seal cap
(see Figures 15 & 16 on Page 13) in each fl ue
outlet.
PRODUCT REFERENCE INFORMATION
Cat.
Model
Ship
No.
Wt.
H3335
SSDVPF-CNM
270 lbs
H3336
SSDVPF-CNE
270 lbs
EFFICIENCIES
SSDVPF
58 % (NG)
61 % (LP)
72 % (NG)
Steady State
73 % (LP)
68 % (NG)
• AFUE
68 % (LP)
Left Side View
Figure 14
12
• Inches (millimeters)
• Minimum Framing Stud Size is 2 x 4
• See right side viewsof fi replace below for gas line inlet location options.
37,500
(MV Low 30,000)
4-1/2" Inner
Vent Center - Top
7-1/2" Outer
Vent with one 90
degree elbow
12-1/8
(308)
5-1/8
(130)
Vent Center- Side
Vent (no elbows)
12-1/8
(308)
Ship.
Volumn
52W x 27D x 44-
1/2H (36.2 cu.ft).
52W x 27D x 44-
1/2H (36.2 cu.ft).
* This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing
spacers. (The 41-1/2 in. dimension permits easier fi replace installation, if unit is installed after framing is erected).
** This dimension based on 5/8" drywall. For 1/2" drywall use 25-1/2" (648 mm). The fi nished dimension should be 26-1/2" (673 mm).
See also, Side Vent Seal Cap note below.
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening,
10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 19).
FINISH WALL BRACKET
(Front, back, and left edge of unit top)
24
(610)
41
(1041)
24
(610)
18-1/4
(464)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Fireplace Framing Specifi cations
**25-1/4
(641)
Dimension A
Secure Vent 47-1/8 (1194)
Secure Flex 47-7/8 (1216)
10-1/2
(267)
5-1/8
A
(130)
Center of gas line
is 3 in. (76 mm)
up from floor.
26-3/4
(648)
Secure Vent - 46-1/2 (1181)
Secure Flex - 48-1/4 (1226)
Gas Line Center of gas line is 3 in. (76 mm) up from fl oor.
10
(254)
FLUE
(Top or Side)
40-1/8
(1019)
Top View
43-5/8
(1108)
1/2
(13)
34-3/8
(873)
2-1/2
24
(63.5)
(610)
Louvered Control
Front View
Compartment Door
inches (millimeters)
11-3/8
10-1/2
(267)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
A
5-1/8
26-3/4
(130)
(679)
Gas Line
Dimension A
43-5/8
(1108)
Stepped to Accept Drywall on 2 Corners
FRAMING SPACERS
(Top and Side)
12 (305)
FINISH WALL BRACKET
5/8
(16)
3-1/2 (89)
2-1/2
(63.5)
4 (102)
37
(940)
Provide
additional
space for Side
Vent Seal Cap
if installing
against a solid
wall.
3 (76)
6-7/8
(175)
Minimum Framing
Stud Size is 2 x 4
Vent Framing - Top Vent
With One 90º Elbow
Vent Framing - Rear Vent
With No Elbows
6-1/4
*41-1/2
(159)
(1054)
22-3/4
(578)
DETAIL OF
1/2
(13)
12
(305)
10-1/4
(260)
FLUE
(Top or Side)
ELECTRICAL
INLETS
GAS INLET
Right Side View

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ssdvst-cneSsdvpf-cnmSsdvpf-cne

Table of Contents