For minimum RF emissions, it is essential that the foregoing conditions be
implemented. Failure to do so could compromise the RFI compliance of
the system.
This product, as configured and shipped by Motorola, has been designed
and tested for compliance with the following RFI standards and product
safety regulations:
It is the customer's responsibility to verify compliance if the customer
makes changes or additions to the "as-shipped" configuration.

General Precautions

Operating Environment

When using tape and disk drive units in the MVME956AC chassis observe
the following:
http://www.mcg.mot.com/literature
The VME module front panel screws should be properly tightened
for good grounding.
Electromagnetic Compatibility: FCC class A; European CE Class A
Safety: UL 1950; CSA C22.2/950; VDE EN 60 950; IEC 950
Ensure that the air space above and below the chassis is not blocked,
and that the inlet screens and optional air filter are clean.
The air inlet temperature must not exceed 40 degrees Celsius. If the
MVME956AC is installed in a rack with other chassis, be sure that
each chassis in the rack is provided with its own supply of fresh
cooling air. Do not use air heated by one chassis to "cool" another
chassis.
All unused VME module slots must be covered to prevent cooling
air and/or RF emissions from escaping from the chassis.
The chassis should be used only in a clean environment such as an
office or lab.