en | Installation
4.4.5

Data Interface

The bidirectional data interface of each VIP X1600 module is used to control the connected
units, for example a dome camera with motorized lens. The connection supports the RS232,
RS422 and RS485 transmission standards.
Each VIP X1600 module offers the serial interface via the orange terminal block (see
Section 8.7 Terminal Block, page 115).
The range of controllable equipment is expanding constantly. The manufacturers of the
relevant equipment provide specific information on installation and control.
CAUTION!
Please take note of the appropriate documentation when installing and operating the unit to
!
be controlled.
The documentation contains important safety instructions and information about permitted
uses.
NOTICE!
i
A video connection is necessary to transmit transparent data.
4.4.6
Alarm Inputs
Each VIP X1600 module has four alarm inputs on the orange terminal block (see
Section 8.7 Terminal Block, page 115). The alarm inputs are used to connect to external alarm
devices such as door contacts or sensors. When configured appropriately, an alarm device
can, for example, trigger the VIP X1600 module to automatically establish a connection with a
remote station.
A zero potential make contact or switch can be used as the actuator.
NOTICE!
i
If possible, use a bounce-free contact system as the actuator.
4.4.7

Relay Outputs

Each VIP X1600 module has four relay outputs for switching external units such as lamps or
alarm sirens. You can operate these relay outputs manually while there is an active connection
to the VIP X1600 module. The outputs can also be configured to automatically activate sirens
or other alarm units in response to an alarm signal. The relay outputs are also located on the
orange terminal block (see Section 8.7 Terminal Block, page 115).
CAUTION!
!
A maximum load of 30 V and 2 A may be applied to the relay contacts.
V3.5 | 2007.12
Connect the lines to the appropriate terminals on the orange terminal block (IN1 to IN4)
and check that the connection is secure.
Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4)
and check that the connection is secure.
Installation and Operating Manual
VIP X1600
Bosch Security Systems