11,12,13,14,
15,16
In the second line,
from the left to the
right:
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5 NC5
CTRL 12V
+12V
485 A/B
3.8.1.5 2U Series
You can refer to the following sheet and
In the first line, from
the left to the right,:
1,2,3,4,5,
6,7,8,9,10,
11,12,13,14,
15,16
In the second line,
from the left to the
right:
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5 NC5
CTRL 12V
+12V
485 A/B

3.8.2 Alarm Input Port

The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
Control power output. You need to close the device power to cancel
the alarm.
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.
F igure 3-6
X 2 8 8 H 2 8 8 H 2 8 8 H
Figure 3-7
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
Control power output. You need to close the device power to cancel
the alarm.
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.
for alarm input and output information.