Install the access panel (on page 20).
10.
Install the server into the rack
11.
Install the drives
12.
CAUTION:
all bays are populated with either a component or a blank.
Power up the server (on page 17).
13.

Mini-SAS cable option

The Mini-SAS cables in this option kit support the following drive configurations:
Drive configuration
Four-bay LFF
Four-bay LFF
Eight-bay SFF
Eight-bay SFF
To connect the cable option:
Power down the server (on page 17).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 17).
o
Remove the server from the rack (on page 18).
o
Remove the access panel (on page 19).
4.
Remove the PCI riser cage (on page 20).
5.
Install the storage controller
6.
Connect the common end of the Mini-SAS cable to the controller option.
7.
Install the PCI riser cage (on page 21).
8.
Route the Mini-SAS cable along the side of the system board towards the front chassis, and then connect
9.
the cable to the drive backplane.
("Installing the server into the
("Installing a hot-plug
drive" on page 32).
To prevent improper cooling and thermal damage, do not operate the server unless
HP Smart Array RAID Controller
H220 or P420
H222 or P222
P822
H220 or P420
("Installing a storage
rack" on page 27).
Expansion slot
Full height or low
profile
Full height or low
profile
Full height
Low profile
controller" on page 38).
Hardware options installation 35
Mini-SAS cable
800 mm
890 mm
615 mm and 800 mm
615 mm and 800 mm