Omron V500-R2 Series User Manual page 112

Fixed laser-type barcode reader
Hide thumbs Also See for V500-R2 Series:
Table of Contents

Advertisement

Section 5
Example of System Configuration
Upper connection port specification
A port to connect with the upper equipment using RS-232C. A dust cover is attached
before shipping. Remove it when used.
Connector specification
Cable length
Communication system
Synchronous system
Communication control system
Communication speed
Character format (fixed)
Check code (Error detection system)
Pin arrangement
Connector cap is not conducting with GR (frame ground).
Pin No. Signal name
1
2
3
4
5
6
7
8
9
RS signal control from the upper equipment
In case of 1: N connection with RS-232C interface of the upper equipment, the RS signal of the
upper equipment should be input to the CS signal of the link unit. Turn OFF the RS signal within
15ms after data transmission is finished. This control should be performed for normal operation.
V500-R2 series
110
User's Manual
Item
D-sub 9 pin Connector plug Lock screw: #4-40UNC
Max. 15 m
In compliance with RS-232C
Asynchronous system
One-to-N procedure dedicated to OMRON
4800/9600/19200/38400 bps (Set with DIP-SW)
FCS (Frame Check Sequence)/Vertical parity system
Function
-
Not connected
RD
Received data
SD
Transmission data
-
Not connected
SG
Ground for signal
-
Not connected
Transmission request (Normally
RS
ON when operating)
CS
Transmission allowed
-
Not connected
Turn ON only in case when data is transmitted from upper equipment.
Upper side RS
Upper side SD
Specification
Start bit
Data bit
Parity bit
1
8
5
4
3
2
1
Signal direction
-
Input
Output
-
-
-
Output
Input
-
Within 15 ms
Stop bit
None
1
9
8
7
6
Total
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V500-r2cf

Table of Contents