Omron V500-R2 Series User Manual page 105

Fixed laser-type barcode reader
Hide thumbs Also See for V500-R2 Series:
Table of Contents

Advertisement

Setting at bar code reader side
Set as follows, using EDA command (collective setting for link unit connection).
p.61
Setting item
Communication speed
Data length
Parity
Stop bit
Header
Footer
RS/CS control
Process when reading is NG
Other setting
Setting at link unit V700-L12 side
Setting item
Machine No.
Set the machine No. differing in each link unit
Communication
9600 bps
speed
Transmission
Normal procedure (polling procedure)
procedure
Connection check
None
RS-485 termination
2 sets on both sides of transmission path are
resistance
turned ON (*)
*
In case of connection example shown here, termination resistors of the machine No. 3 and the upper
equipment (interface converter) are turned ON.
Specification and wiring of the link unit p.103
Setting content
9600 bps
8-bit
Even number
1-bit
None
CR
None
? [CR] or > [CR] is transmitted 5H
Same as factory default
setting.
Setting content
Example of System Configuration
Command
(Same as initial setting)
(Same as initial setting)
L3
(Same as initial setting)
(Same as initial setting)
(Same as initial setting)
P0
-
Setting
Set DIP-SW 1 to 5.
DIP-SW 6, 7 are OFF
DIP-SW8 is OFF
DIP-SW9 is OFF
In case when turned ON, DIP-
SW10 is ON
V500-R2 series
Section 5
103
User's Manual