Troubleshooting

With controllers or status monitor
Your Rinnai continuous flow water heater has a self diagnostic capability. If a fault occurs, an
error code will flash on the digital monitor (if you have water controllers) or status monitor
(selected models only). This assists with diagnosing the fault and may enable you to overcome
a problem without a service call. Please quote the code displayed when contacting Rinnai.
Common
Fault
Error Codes
-
Noticeable reduction of water flow.
03
Power interruption during bath fill, water will
not flow when power is back on.
10
Air intake or flue blocked.
11
No ignition, no gas supply.
12
Flame failure, low gas flow.
14
Over heat thermal fuse.
16
Over temperature warning.
25
Condensate trap error
32
Outgoing water temperature sensor faulty.
33
Heat exchanger outlet sensor faulty.
34
Air temperature sensor faulty (internal only)
52
Gas modulating valve faulty.
61
Combustion fan failure.
65
Water flow control faulty (does not stop flow
properly).
71
Microprocessor failure.
72
Microprocessor failure.
LC (00)
Scale build-up in heat exchanger (when
checking maintenance code history, 00 is
substituted for LC)
In all cases you may be able to clear the error code by turning the hot water tap off, then on
again. If this does not clear the error code, try pushing the On/Off button Off, then On again. If
the error code remains, contact Rinnai for advice.
Rinnai New Zealand Ltd
Possible Solution
Inlet water filter needs to be cleaned. Service call.
Turn off all hot water taps and press On/Off twice.
Service call.
Check gas is turned on at water heater and gas meter
or cylinder.
Check gas is turned on at water heater and gas meter
or cylinder. Check there are no obstructions to the flue
outlet.
Service call.
Service call.
Condensate container is full.
Check condensate drain for blockage.
Replace condensate trap.
Service call.
Service call.
Check sensor wiring for damage.
Measure resistance of sensor.
Check combustion fan.
Check internal flue leakage.
Check flue system integrity.
Replace sensor.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Continuous Flow Water Heater Operation Manual